A property of a measurement system in which each
input or output channel is digitized or updated at the same instant. You will
need simultaneous sampling for applications where the time relationship
between inputs is important, such as phase analysis of AC signals.
Because channel-dedicated analog-to-digital
converters (ADCs) are used to sample data simultaneously between inputs, the
maximum sample rate is applicable to each channel and is not divided by the
total number of channels. Devices that don’t have simultaneous sampling
capabilities use multiplexing to connect each channel to its ADC.
Interval scanning is a low-cost option to simulate simultaneous sampling for
low-frequency signals such as temperature or pressure. This method scans the
input channels at one interval and uses a second interval to determine the
time before repeating the scan. The input channels are scanned within
microseconds, creating the effect of simultaneously sampling the input
channels.
No
板載內(nèi)存
4095 樣本
模擬輸出
Number of Channels
2
Resolution
16 bits
Maximum Voltage Range
Range
-10 V - 10 V
Accuracy
3.512 mV
Minimum Voltage Range
Range
-10 V - 10 V
Accuracy
3.512 mV
Update Rate
250 kS / s
Current Drive Single
2 mA
Current Drive All
4 mA
Digital I / O
Bidirectional Channels
32
Input-Only Channels
0
Output-Only Channels
0
Timing
軟體
Logic Levels
TTL
Programmable Input Filters
否
Supports Programmable Power-Up States?
是
Digital Input
Input Type
汲極 源電流
Maximum Voltage Range
0 V - 5.25 V
Digital Output
Output Type
Current Flow
A sinking device provides a path for the
current to ground and is not responsible for powering the device. Terms used
to describe sinking devices include NPN, Open Collector, Normally High, and
IEC Negative Logic.
A sourcing device provides the power or a
positive potential. Sourcing devices ''push'' the current through the load.
Terms used to describe sourcing devices include PNP, Open Emitter, Normally
Low, and IEC Positive Logic.
Relays are ified by their number of poles and number of throws.
The pole of a relay is the terminal common to every path. Each position that
the pole can connect to is called a throw. A relay can be made of n poles and
m throws. For example, a single-pole single-throw relay (SPST) has one pole
and one throw.
·Form A relays are SPST with a default state of normally
open.=
·Form B relays are SPST with a default state of
normally closed.
·Form C relays are SPDT and break the connection
with one throw before making contact with the other (break-before-make)..
汲極 源電流
Current Drive Single
16 mA
Current Drive All
50 mA
Maximum Voltage Range
0 V - 3.8 V
Counters / Timers
Watchdog Timer
Digital I/O Watchdogs
NI digital I/O watchdogs are an innovative
technology that provides protection against a wide variety of fault
conditions:
·Computer crash - total OS crash
·Application crash - software application ceases to respond
·Driver crash - device driver ceases to respond
·PCI bus failure - communications cease to respond
With watchdogs, the digital outputs go to a safe
state when a fault condition is detected and the watchdog timer expires for
safe recovery. Watchdogs are important whenever the module is connected to
actuators such as pumps, valves, motors, and relays. The digital I/O module
monitors the software application and, if it fails to respond within the time
limit, automatically sets the output lines to a user-defined safe state. The
module remains in the watchdog state until the watchdog timer is disarmed by
the application and new I/O values are written, the device is reset, or the
computer is restarted.
Product Family
多功能DAQ
Measurement Type
電壓
相位差編碼
Form Factor
USB
Operating System / Target
Windows
RoHS Compliant
是
Isolation Type
None
模擬輸入
Single-Ended Channels
16
差分通道
8
模擬輸入分辨率
16 bits
*電壓范圍
Range
-10 V - 10 V
Accuracy
2.71 mV
Sensitivity
118 μV
Minimum Voltage Range
Range
-200 mV - 200 mV
Accuracy
0.089 mV
Sensitivity
5.2 μV
Number of Ranges
4
Simultaneous Sampling
Simultaneous Sampling
A property of a measurement system in which each input or output channel is digitized or updated at the same instant. You will need simultaneous sampling for applications where the time relationship between inputs is important, such as phase analysis of AC signals.
Because channel-dedicated analog-to-digital converters (ADCs) are used to sample data simultaneously between inputs, the maximum sample rate is applicable to each channel and is not divided by the total number of channels. Devices that don’t have simultaneous sampling capabilities use multiplexing to connect each channel to its ADC.
Interval scanning is a low-cost option to simulate simultaneous sampling for low-frequency signals such as temperature or pressure. This method scans the input channels at one interval and uses a second interval to determine the time before repeating the scan. The input channels are scanned within microseconds, creating the effect of simultaneously sampling the input channels.
No
板載內(nèi)存
4095 樣本
模擬輸出
Number of Channels
2
Resolution
16 bits
Maximum Voltage Range
Range
-10 V - 10 V
Accuracy
3.512 mV
Minimum Voltage Range
Range
-10 V - 10 V
Accuracy
3.512 mV
Update Rate
250 kS / s
Current Drive Single
2 mA
Current Drive All
4 mA
Digital I / O
Bidirectional Channels
32
Input-Only Channels
0
Output-Only Channels
0
Timing
軟體
Logic Levels
TTL
Programmable Input Filters
否
Supports Programmable Power-Up States?
是
Digital Input
Input Type
汲極
源電流
Maximum Voltage Range
0 V - 5.25 V
Digital Output
Output Type
Current Flow
A sinking device provides a path for the current to ground and is not responsible for powering the device. Terms used to describe sinking devices include NPN, Open Collector, Normally High, and IEC Negative Logic.
A sourcing device provides the power or a positive potential. Sourcing devices ''push'' the current through the load. Terms used to describe sourcing devices include PNP, Open Emitter, Normally Low, and IEC Positive Logic.
Relays are ified by their number of poles and number of throws. The pole of a relay is the terminal common to every path. Each position that the pole can connect to is called a throw. A relay can be made of n poles and m throws. For example, a single-pole single-throw relay (SPST) has one pole and one throw.
· Form A relays are SPST with a default state of normally open.=
· Form B relays are SPST with a default state of normally closed.
· Form C relays are SPDT and break the connection with one throw before making contact with the other (break-before-make)..
汲極
源電流
Current Drive Single
16 mA
Current Drive All
50 mA
Maximum Voltage Range
0 V - 3.8 V
Counters / Timers
Watchdog Timer
Digital I/O Watchdogs
NI digital I/O watchdogs are an innovative technology that provides protection against a wide variety of fault conditions:
·Computer crash - total OS crash
·Application crash - software application ceases to respond
·Driver crash - device driver ceases to respond
·PCI bus failure - communications cease to respond
With watchdogs, the digital outputs go to a safe state when a fault condition is detected and the watchdog timer expires for safe recovery. Watchdogs are important whenever the module is connected to actuators such as pumps, valves, motors, and relays. The digital I/O module monitors the software application and, if it fails to respond within the time limit, automatically sets the output lines to a user-defined safe state. The module remains in the watchdog state until the watchdog timer is disarmed by the application and new I/O values are written, the device is reset, or the computer is restarted.
否
Counters
2
Buffered Operations
是
Debouncing / Glitch Removal
是
Max Source Frequency
80 MHz
Pulse Generation
是
Size
32 bits
Time Stability
50 ppm
Logic Levels
TTL
Timing / Triggering / Synchronization
Triggering
數(shù)位
Physical Specifications
Length
16.9 cm
Width
9.4 cm
Height
3.1 cm
I / O Connector
螺絲端子
USB Power